NH3 Receigerant Flow Sensor

INFRARED HCFC & AMMONIA (NH3) REFRIGERANT SENSOR User …

The IR Refrigerant Gas Sensor must be placed in locations that a refrigerant gas leak is likely to occur and where refrigerant gas is likely to concentrate so as to provide warning of a potential hazardous condition. Mounting locations are dependant upon the application and the refrigerant gas to be monitored. The housing has a ¾” conduit knockout hole in the bottom so the sensor must be …

Get Price

Chat With WhatsApp

(NH3) Ammonia Gas Detection | Sensidyne

Experts in Ammonia Gas Detection Ammonia (NH 3) is a colorless gas or compressed liquid with an extremely pungent odor. It reacts violently with water and can seriously damage the skin, eyes and respiratory system. The gas has a density of relative to air () and is …

Get Price

Chat With WhatsApp

How to Detect nh3 density sensor

How to Detect nh3 density sensorModel: HCFC NH3 IR Sensor IRHCFCNH3_All Rev: - 3 - GENERAL The non-dispersive IR refrigerant gas sensor was designed to detect for the presence of certain refrigerant gases within an enclosed space. The sensor is mounted within the space to be monitored and connected by cable to a monitoring device.

Get Price

Chat With WhatsApp

Level Controls | Hansen Technologies

These compact Single Point Level Sensors and Switches are economical solutions for reliable and accurate level detection. They are designed to detect the presence of ammonia or halocarbon refrigerant liquid (but not oil) at a specific location in vessels containing refrigerant by …

Get Price

Chat With WhatsApp

Ammonia Gas Detection | Sensidyne

The Factory Mutual (FM) approval is a certification that the sensor can detect low PPM Ammonia reliably and repeatedly within the specified response times and accuracy. Sensidyne offers four different range Ammonia sensors including a long-life version commonly used for process leak detection. FM performance certification can have a favorable effect on facility hazard analysis for insurance ...

Get Price

Chat With WhatsApp

Easy to service sensors - ammonia refrigeration systems

NH3 Refrigerant Level Sensor (AKS41) NH3 Level Controller; NH3 Compressor Protection; pH Sensor - Suitable for NH₃/brine leakage detection; NH3/Brine leakage Display; Multi Display - pH Controller & Display; NH3 leakage alarm/sensor; CO 2 Sensors. CO 2 Switch - 24 V AC/DC; CO 2 Switch - 90...240 V AC; CO 2 switch - Low temperature ; CO 2 Refrigerant Level Sensor; CO 2 Level Sensor - Flexible ...

Get Price

Chat With WhatsApp

Instruction manual HBLT-Wire LEVEL SENSOR

HBLT-Wire is an intelligent sensor with an in-built microprocessor. It is designed for continuous level measurement of liquid NH3 refrigerant in refrigeration systems. The sensor emits a 4-20mA analogue signal, which is proportional to the liquid level. The construction of the sensor makes it suitable for systems with pressure of up to 100 bar.

Get Price

Chat With WhatsApp

Refrigerant Flow Sensors: High Pressure Refrigerant Flow ...

2017-03-21· Refrigerant Flow Sensors – Measuring Refrigerant Flow. In addition to a wide range of stock flow sensors, Titan Enterprises develop flow meters for specific applications – in this case, refrigerant flow new, high pressure version of the Titan 900 Series turbine flow meter is now available for measuring refrigerant flow. The new refrigerant flow sensors are adapted with steel …

Get Price

Chat With WhatsApp

I have a 2012 camry no a/c have code b1479 my scan tool ...

2018-09-18· The A/C flow sensor, which is mounted on the compressor, is used to detect the amount of refrigerant flow. The A/C flow sensor converts the amount of refrigerant flow that is detected to a voltage value to send it to the air conditioning amplifier assembly. The voltage value sent from the A/C flow sensor changes depending on the amount of refrigerant flow. As the amount of refrigerant flow ...

Get Price

Chat With WhatsApp

NH3, Water & Alcohol - HB Products

Gas Flow Control ; Displaying. pH Display & Control; Level Display & Control ; Temperature Sensor. Proces Installation; Wall Mounting; ATEX - Zone 0 & 1; Pressure Sensor . Proces Installation ; Motorized Control Valves. Modulating Valves; Stepper Motor Valve; Position Sensor. Compressor Position Sensor. Linear sensor - Short stroke; Linear sensor - Long stroke ; Position sensor ; ATEX - Zone 0 ...

Get Price

Chat With WhatsApp

Testo 316-4 Set 2 - Leak Detector for Ammonia (NH3 ...

The testo 316-4 set 2 with leak detector for ammonia (NH3) including refrigerant sensor head, case, mains unit and earphones – for fast, reliable leak location. Product Description Leaks on a refrigeration system have very serious consequences: the required cooling capacity is reduced and, in the worst case scenario, the system may suffer damage.

Get Price

Chat With WhatsApp

VisaGage II NH3 Flow Monitor and Blockage System - John Blue

Monitor NH 3 (anhydrous ammonia) or N-Serve flow rates from the tractor cab. The NH 3 VisaGage is manufactured from polymethylpentene (TPX®) chemical resistant bodies with UV protection, polypropylene balls and ball screen, Buna-N o-rings and aluminum manifolds. For best results the NH 3 VisaGage should be mounted to the Blockage Monitor System. Maximum allowed pressure in the …

Get Price

Chat With WhatsApp

Testo 316-4 Set 2 - Leak Detector for Ammonia (NH3 ...

Muser Apac Sdn Bhd - Testo 316-4 Set 2 - Leak Detector for Ammonia (NH3) [Delivery: 3-5 days subject to availability] Refrigerant Leak Detectors Pressure / Air Flow / Gas Detectors Testo Kuala Lumpur (KL), Malaysia, Selangor, Sunway Velocity Supplier, Suppliers, Supply, Supplies, Muser provides a comprehensive range of test & measuring instruments, laboratory supplies, and solutions.

Get Price

Chat With WhatsApp

HBLT-Wire Refrigerant wire sensor in refrigeration system

HBLT-Wire - Refrigerant wire sensor. HBLT-wire is a capacitive sensor for level measurement of NH3 refrigerant in industrial refrigeration systems. The sensor has an output signal of 4-20 mA, which is proportional with 0 and 100%. Its output signal is 4 mA for an empty container and 20 mA for a full container. HBLT-wire can be adjusted in ...

Get Price

Chat With WhatsApp

Codes and Design Specifications

(minimum 1 sensor) GG-NH3-2% 10,000 ppm - Redundant Emergency Ventilation 20,000 ppm - De-energize pumps, compressors, and normally closed valves Vent Line GG-VL2-NH3 1% - Alarm to monitored location Refrigerated Areas GG-NH3-100 25 ppm - Alarm to monitored location 35 ppm - Close liquid and hot gas solenoid valves Packaged Systems GG-NH3-100 25 ppm - Alarm to monitored …

Get Price

Chat With WhatsApp

Codes and Design Specifications

Provide (1) GG-NH3-2% ammonia gas sensor for each Compressor Room. Locate sensor 5 feett off the floor below the emergency ventilation fan so it samples airflow from throughout the room. The sensor shall have potted electronics to protect circuit board and components. The sensor shall have a polycarbonate enclosure to prevent corrosion.

Get Price

Chat With WhatsApp

Professional gas sensing solution supplier with over 30-year gas sensor manufacturing experience Contact Us