DPWQ502000 - Wall mounting CO2 and VOC sensor with a 0 to 10 Vdc output. DCTF000320 - ANTIFREEZE THERMOSTAT 3M CAPILLAR CONTACT 24-230V. DPWQ306000 - Wall mounting VOC sensor with a 0 to 10 Vdc or 4 to 20 mA output. £ £ On request. SKU. DPWQ306000. Qty: Add to Cart. Trustpilot. Overview. Manuals & Datasheets. DATA-SHEET . Product type: Sensors & …
Wall Mount CO2 /Temp Sensor with out display,0/2-10Vdc or 0/4-20mA output. Product Info; Literature ; Overview. The C7262 Sensor is a stand-alone carbon dioxide (CO2) and temperature sensor for use in determining ventilation necessity with HVAC controllers. The C7262 measures the CO2 concentration and temperature to control the amount of fresh outdoor air supplied to maintain acceptable levels ...
DPWQ502000 - Wall mounting CO2 and VOC sensor with a 0 to 10 Vdc output. DPWQ402000 - Wall mounting CO2 sensor with a 0 to 10 Vdc output. £ £ On request. SKU. DPWQ402000. Qty: Add to Cart. Trustpilot. Overview. Manuals & Datasheets. DATA-SHEET . Product type: Sensors & Stats: IP rating: IP30: Output Signal: 0..10Vdc: Manufacturer: Carel : Sensor Type: Air Quality: Sensor ...
Terminal Block Torque to N-m ( to in-lbf) CO2 TRANSMITTER Sensor Type Non-dispersive infrared (NDIR), diffusion sampling Output Range 0 to 2000/5000 ppm (selectable) Accuracy ±30 ppm ±3% of measured value Repeatability ±20 ppm ±1% of measured value Response Time <60 seconds for 90% step change VOC TRANSMITTER OPTION Sensor Type Solid state Output Range 0 …
Aaon R17350 SENSOR CO2 WALL MNT 0-10VDC-Aaon R17350 SENSOR CO2 WALL MNT 0-10VDC SENSOR CO2 WALL MNT 0-10VDC Manufacturer: Aaon Part Number: R17350
HVAC transmitter to measure temperature, relative humidity, CO2 (carbon dioxide) and ambient light level. The supply voltage is 24 VAC or 24 VDC. The green, yel
Honeywell C7632B1002 - Duct Mount CO2 Sensor w/ No Display, 0-10 Vdc Fixed Output - CO2 Sensors offer a fixed 0-2000ppm & fixed 0-10Vdc output, determine ventilation need with HVAC controllers and measure CO2 concentration in ventilated …
Typical values ( watts peak, watts avg. @ 42 VDC) *Note: The Telaire product line offers patented ABC Logic™ software for self-correction of drift to better than ±20 ppm per year. The system is virtually free of maintenance and typically has than 10 …
Honeywell C7262A1016 - Wall Mount CO2/Temp Sensor w/ out Display, 0/2-10Vdc or 0/4-20mA Output - The C7262 Sensor is a stand-alone carbon dioxide (CO2) and temperature sensor for use in determining ventilation necessity with HVAC controllers. The C7262 measures the CO2 concentration and temperature to control the amount of fresh outdoor air supplied to maintain acceptable levels of CO2 …
CO2 TRANSMITTER (0-10 VDC) OUT C OUT R AIR FLOW MEASURING STATION (0-10 VDC) FILTER DPS SAT SENSOR OAT Mod. Heat (0-10 VDC) Installation Guide VT8600 Series 7 Viconics Technologies Inc. | 9245 Langelier Blvd. | St.-Leonard | Quebec | Canada | H1P ...
DPDQ402000 - Duct mounting CO2 sensor with a 0 to 10 Vdc output Carel Duct mounting CO2 Air quality sensor with a 0..10V output The store will not work correctly in …
Wall Mount CO2 Sensor w/ No Display, 0-10 Vdc Fixed Output C7632A1004 Wall Mount CO2 Sensor w/ No Display, 0-10 Vdc Fixed Output. SKU: C7632A1004 Honeywell. SKU: C7632A1004. Brand: Honeywell-+ $ each ADD TO CART. Add to List. List. Add …
Dwyer CDT-2W40 - CO2 Wall Sensor & Temperature Transmitter, 4-20 mA (0-10 VDC) - The Series CDT Carbon Dioxide and Temperature Transmitters accurately monitor the CO2 concentration and temperature in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength nondispersive infrared (NDIR) sensor is used to automatically correct …
Mount Sensor Telaire Ventostat ... Analog 0 to 10 VDC (100 ohm output impedance) Power Supply Requirements 18 to 30 VAC RMS, 50/60 Hz or 18 to 42 VDC, polarity protected. Power Consumption Typical values ( watts peak, watts avg. @ 42 VDC) *Note: The Telaire product line offers patented ABC Logic™ software for self correction of drift to better than ±20 ppm per year. The system …
DPWQ402000 - Wall mounting CO2 sensor with a 0 to 10 Vdc output Carel Wall mounting CO2 Air quality sensor with a 0..10V output
• Fixed 0 to 10 Vdc from 0 to 2000 ppm. No adjustments are necessary. • Compatible with Honeywell Excel 10, 15, 5000, and any controller requiring 0-10 Vdc input. SPECIFICATIONS Models: C7632 Sensor and Controller. A stand-alone car-bon dioxide (CO2) sensor with one 0-10 Vdc analog out-put. C7632A: Wall mount model. C7632B: Duct mount model.
Veris CDE - Carbon Dioxide (CO2) Sensor (NDIR, Duct Mount) - The CDE is a non-dispersive infrared (NDIR) sensor designed for measuring environmental CO2 concentration in ventilation systems and indoor living spaces. Its measurement range of 0 to 2000 ppm makes it compliant with ASHRAE and other standards for ventilation control. The CDE Series provides a user-selectable 4 to 20 mA or 0 to 10 ...
Universal outputs for both carbon dioxide and relative humidity allow users to select the transmitter output to be 4 to 20 mA, 0 to 5 VDC, or 0 to 10 VDC to work with virtually any building management controller. Additionally, passive thermistor or RTD sensor can be ordered for a temperature output. For applications that require visual indication, the wall mount configurations of the Series ...